Guide your way through the CTO with ASAHI Gaia Series by using deflection and direction control.

Guide wire with a high maneuverability in the chronic total occluded lesion, and a micro-cone tip designed to improve penetrability into the lesion while
remaining flexible.

■Deflection and Torque Control
To guide the wire through the occlusion to the distal lumen by using deflection and rotational control.

■Controllability
Within strong resistance area, ASAHI Gaia experiences higher torque response and less whip motion.

■Penetrability by micro-cone tip
The ball tip was made smaller to increase its penetration efficacy.
It makes easier to create the entry route to the hard tissue and fibrous cap.

■Tip flexibility
By taking advantage of tip flexibility, ASAHI Gaia easily avoids hard tissue and advances smoothly.
Deflection control: Guiding the wire to the distal true lumen with rotational control by using deflection which occurs when advancing a shaped GW.

■1mm pre-shaped tip
The pre-shape of the tip is incorporated in the production process, significantly increase tip shape retention.

* All the data were obtained by company standardized test, which may differ from industry standardized tests.
* All the data do not prove that all devices have exactly the same performance with the samples used for these tests.

Technology

Product Spec

Tip Load 1.7gf / 3.5gf / 4.5gf
Tip Shape Pre-shape
Radiopaque Length 15cm
Coating Hydrophilic
Usable Length 190cm / 300cm
Structure
Category

Order Information

Product Name Catalog No. Tip Shape Usable Length Outer Diameter Coil Length Radiopaque Length Coating Coating Length
ASAHI Gaia First AHW14R007P Pre-shape 190cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia First AHW14R307P Pre-shape 300cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia First AHW14R007S Straight 190cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia First AHW14R307S Straight 300cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Second AHW14R008P Pre-shape 190cm 0.28/0.36mm (0.011/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Second AHW14R308P Pre-shape 300cm 0.28/0.36mm (0.011/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Second AHW14R008S Straight 190cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Second AHW14R308S Straight 300cm 0.26/0.36mm (0.010/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Third AHW14R011P Pre-shape 190cm 0.30/0.36mm (0.012/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Third AHW14R311P Pre-shape 300cm 0.30/0.36mm (0.012/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Third AHW14R011S Straight 190cm 0.30/0.36mm (0.012/0.014") 15cm 15cm Hydrophilic 40cm
ASAHI Gaia Third AHW14R311S Straight 300cm 0.30/0.36mm (0.012/0.014") 15cm 15cm Hydrophilic 40cm

“ASAHI”, “ASAHI Gaia" and "ACT ONE" are trademarks or registered trademarks of ASAHI INTECC CO., LTD. in Japan and other countries.
Coated with SLIP-COAT® coating.

The tip load values of our guide wires are the values assuming the force that the tip of the guide wire pushes the lesion on the basis of company standardized test.
There are individual differences in values of actual devices.

Inquiry about Asahi Intecc medical products

SHARE THIS PAGE